Electrical Engineer jobs

Staff Electrical Engineer

Mission Critical GroupSpicewood, TXFull-timeOn-sitePosted 9 days ago

Pay not listed

Key facts

Experience
10+ years
Degree
Bachelor's degree

Looks real. 1 thing to check before you apply.

On Mission Critical Group’s own careers site (SmartRecruiters), checked open today.

  • To check: No pay range listedAsk for the pay range before you interview.
  • Checked: On the company's own careers siteSmartRecruiters board
  • Checked: Checked open todaySmartRecruiters board
  • Checked: No reposts foundSmartRecruiters board
  • Trust score 89 / 100 · Looks good
See all 5 checksShow fewer
How we check

What you’ll do

  • Define protection philosophies and scheme selection for substations, transformers, generators, and MV/LV distribution systems.
  • Lead and review power system studies, protection schemes, relay settings, and protection and control diagrams.
  • Set design standards and develop modeling and protection approaches for Intermediate Voltage DC systems.
  • Review protection work across projects and support field testing, commissioning, energization, and troubleshooting.

Summarised from the posting by AI and can be wrong. The full description is the source.

Requirements

Licenses and certifications

  • PE license (preferred)
  • NETA or advanced protection, generator controls, or automation certifications (preferred)

Experience

  • 10+ years in power system protection and utility or industrial power design
  • Hands-on experience across multiple relay and OEM platforms (SEL, GE, Schneider Electric, Eaton, Siemens, ABB)
  • Data center, utility substation, generation, or industrial plant protection experience (preferred)
  • Relay testing and commissioning experience (Omicron, Doble) (preferred)

Education

  • Bachelor’s in Electrical Engineering or a related field

Skills

  • Proficiency in power system analysis tools (ETAP, SKM PowerTools, EasyPower, or ASPEN)
  • Deep knowledge of protective relaying principles and substation protection schemes
  • Deep knowledge of substation automation, IEC 61850, and SCADA communications
  • Deep knowledge of NEC, NFPA 70E, and ANSI/IEEE protection standards
  • Computer-Aided Design program proficiency (REVIT, AutoCAD, Solidworks) (preferred)

Other requirements

  • Proven ability to review others’ work and explain complex protection issues clearly to engineers and customers

Your match

Sign in and add your resume to see which of this job's requirements it shows.

Sign in to check your match

Saved to your account, encrypted. The AI that reads it doesn't keep it or train on it.

Full job description

From Mission Critical Group’s careers site

Company Description

Show full descriptionShow less

Mission Critical Group (MCG) is an end-to-end power solutions and services provider that accelerates time-to-power and delivers scalable, resilient infrastructure for mission critical environments. By integrating engineering, manufacturing, modular deployment, and lifecycle services under one platform, we streamline execution and bring complex projects online faster - without compromising performance. With more than 1.5 million square feet of U.S. manufacturing capacity, MCG supports data centers, power generation, healthcare, oil & gas, pharmaceuticals, semiconductors, and industrial facilities where uptime is non-negotiable. Mission Critical Group designs, manufactures and provides value-added services for customers requiring critical power solutions. Powering a new electric world for a brighter, more secure future.

Job Description

Position Summary

We’re looking for a Staff Electrical Engineer to own the protection philosophy and coordination strategy that keep mission-critical power systems safe, selective, and online.

This is a hands-on, senior technical role, not a people management position. You’ll be the go-to authority on relay protection across large-scale projects: setting the approach, reviewing settings, shaping design standards, and staying involved from study through energization.

Key Responsibilities

  • Define and own protection philosophies and scheme selection for substations, transformers, generators, and MV/LV distribution systems
  • Lead and review power system studies:
  • Short-circuit, load-flow, arc flash, and bus/equipment duty rating validation
  • Time-current coordination for selective tripping across utility, generator, and maintenance modes
  • Develop and review protection schemes and relay settings:
  • Overcurrent, differential, distance, and generator protection, including CT/VT selection
  • Relay setting files and logic using vendor tools (SEL AcSELerator, GE EnerVista, or equivalent)
  • Develop and review AC/DC schematics, wiring, logic, and communications diagrams for protection and control systems, including IEC 61850 / GOOSE and SCADA integration
  • Lead protection design standards that accelerate speed-to-power, and drive Intermediate Voltage DC (IVDC) modeling and protection approaches
  • Serve as technical reviewer for protection work across multiple concurrent projects; approve studies and settings before release
  • Support and troubleshoot field testing, calibration, commissioning, and energization of protection hardware
  • Lead event and mis-operation analysis using relay event records and fault data; drive corrective action
  • Evaluate new relay platforms and protection technologies; mentor engineers across the team

Qualifications

Required Qualifications

  • 10+ years in power system protection and utility or industrial power design
  • Bachelor’s in Electrical Engineering or a related field
  • Proficiency in power system analysis tools (ETAP, SKM PowerTools, EasyPower, or ASPEN)
  • Hands-on experience across multiple relay and OEM platforms (SEL, GE, Schneider Electric, Eaton, Siemens, ABB)
  • Deep knowledge of:
  • Protective relaying principles and substation protection schemes
  • Substation automation, IEC 61850, and SCADA communications
  • NEC, NFPA 70E, and ANSI/IEEE protection standards
  • Proven ability to review others’ work and explain complex protection issues clearly to engineers and customers

Preferred Qualifications

  • PE license strongly preferred; company sponsorship available for licensure
  • Data center, utility substation, generation, or industrial plant protection experience
  • Computer-Aided Design program proficiency (REVIT, AutoCAD, Solidworks)
  • Relay testing and commissioning experience (Omicron, Doble); NETA or advanced protection, generator controls, or automation certifications a plus

Work Environment

Office engineering work combined with field commissioning and collaboration with operations personnel at customer, utility, and infrastructure sites. Expect approximately 25% travel. Field work may involve climbing, lifting, and active industrial or construction environments, plus occasional extended hours or weekend work to meet customer commitments.

Additional Information

A Note to our Recruitment Partners: We really appreciate the interest, but MCG currently manages hiring through our internal team. We love getting to know our candidates directly! Because of this, we don’t accept unsolicited resumes from agencies at this time. If we ever need an extra hand, we’ll be sure to reach out to the community. Thanks for understanding!

MCG is an equal opportunity employer prohibiting discrimination based on race, color, creed, religion, sex, marital status, physical or mental disability, and any other protected classes stated by applicable federal and state laws. DVM is committed to providing equal employment opportunities to qualified individuals with disabilities and to act in accordance with regulations and guidance issued by the Equal Employment Opportunity Commission (EEOC).

Something wrong with this job? Report it · This flag looks wrong

Similar jobs in Texas

Electrical Engineer

ALTEN Technology USA · North Reading, MA +1 place

$120k–$170k/yr

StrongChecked open todayPosted 15 days ago

Electrical Engineer IV

IntelliPro Group Inc. (agency) · Houston, TX

$65–$70/hrContract

StrongChecked open todayPosted 20 days ago

See more like this